|
English
|
正體中文
|
简体中文
|
全文笔数/总笔数 : 17918/22933 (78%)
造访人次 : 7416860
在线人数 : 55
|
|
|
数据加载中.....
|
jsp.display-item.identifier=請使用永久網址來引用或連結此文件:
https://ir.csmu.edu.tw:8080/ir/handle/310902500/23329
|
题名: | Practice and outcomes of airway management in patients with cervical orthoses |
作者: | Liu, YC;Huang, WC;Tan, ECH;Huang, SS;Wang, YK;Chu, YC |
关键词: | Airway management;Cervical collar;Fiberoptic bronchoscopy;Halo vest;Video laryngoscopy |
日期: | 2021 |
上传时间: | 2022-08-05T09:35:32Z (UTC)
|
出版者: | ELSEVIER TAIWAN |
ISSN: | 0929-6646 |
摘要: | Background/purpose: Increasing evidence indicates an association of video laryngoscopy with the success rate of airway management in patients with neck immobilization. Nevertheless, clinical practice protocols for tracheal intubation in patients immobilized using various types of cervical orthoses and the outcomes remain unclear. Methods: We retrospectively assessed the tracheal intubation techniques selected for patients immobilized using cervical orthoses from 2015 to 2018. The endpoints were the intubation outcomes of the different techniques and the factors associated with the selection of the technique. Results: We included 218 patients, 118 of whom wore halo vest braces (halo vest group) and 100 wore cervical collars (collar group). GlideScope video laryngoscopy (GVL) and fiberoptic bronchoscopy (FOB) were the initial intubation methods in 98 and 120 patients, respectively. GVL had a higher first-attempt success rate than did FOB in the collar group (p = 0.002) but not in the halo vest group (p = 0.522). GVL was associated with a lower risk of episodes of SaO(2)< 90% (adjusted relative risk [aRR], 0.11; 95% CI, 0.02-0.67; p = 0.016) and shorter intubation time (aRR,-3.52; 95% CI,- 4.79 similar to-2.25; p < 0.001) in the collar group. However, in the halo vest group, more frequent requirement of a rescue technique (p = 0.002) and necessity of patient awakening (p = 0.001) was noted when GVL was used. Use of the halo vest brace and noting of severe cord compression were independent predictors of the initial selection of FOB. Conclusion: Caution should be exercised when using GVL for tracheal intubation in patients immobilized using halo vest braces. Copyright (C) 2021, Formosan Medical Association. Published by Elsevier Taiwan LLC. |
URI: | http://dx.doi.org/10.1016/j.jfma.2021.02.002 https://www.webofscience.com/wos/woscc/full-record/WOS:000732498800014 https://ir.csmu.edu.tw:8080/handle/310902500/23329 |
關聯: | JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION ,2022,v121,issue 1, P108-116 |
显示于类别: | [中山醫學大學研究成果] 期刊論文
|
文件中的档案:
档案 |
描述 |
大小 | 格式 | 浏览次数 |
index.html | | 0Kb | HTML | 169 | 检视/开启 |
|
在CSMUIR中所有的数据项都受到原著作权保护.
|