    摘要: We report novel methods for detection of hepatitis B surface antigen (HBsAg) based on competitive and sandwiched magnetic immunoassays using functional magnetic nanoparticles in a thin channel. Magnetic nanoparticles labeled with hepatitis B antibody are flowed through a thin channel to form a predeposition layer for capturing HBsAg. Competitive and sandwiched magnetic immunoassays were studied and detection limit, linear range, and sample selectivity were compared. The detection limits of competitive and sandwiched magnetic immunoassays were found to be 0.26 and 0.25 pg/ml, respectively. The linear range of HBsAg concentration was 0.26 pg/ml–2.6 ng/ml for competitive magnetic immunoassay and was 0.89 pg/ml–8.9 ng/ml for sandwiched magnetic immunoassay. The advantages of these methods over ELISA and other methods for HBsAg detection are lower detection limits and wider linear ranges. The running time was less than 30 min. Competitive magnetic immunoassay was faster than sandwiched magnetic immunoassay for detection of HBsAg. The measurements of HBsAg in serum samples from these methods differed by about 10% from those of ELISA. These methods can provide simple, fast, and sensitive detections of biomarkers and other immunoassay-related samples.
    URI: https://ir.csmu.edu.tw:8080/ir/handle/310902500/4355
    http://dx.doi.org/10.1016/j.bios.2010.04.035
    關聯: Biosensors and Bioelectronics
    Volume 25, Issue 12, 15 August 2010, Pages 2701–2705
    显示于类别:[醫學應用化學系暨碩士班] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html期刊論文0KbHTML705检视/开启


    SFX Query

    在CSMUIR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈