中山醫學大學機構典藏 CSMUIR:Item 310902500/24821
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 17918/22933 (78%)
造访人次 : 7438104      在线人数 : 92
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.csmu.edu.tw:8080/ir/handle/310902500/24821


    题名: Effectiveness of N95 Facepiece Respirators in Filtering Aerosol Following Storage and Sterilization
    作者: Lin, TH;Tseng, CC;Huang, YL;Lin, HC;Lai, CY;Lee, SA
    关键词: N95;Storage;COVID-19;Autoclave;Gamma irradiation;Filtration performance
    日期: 2020
    上传时间: 2022-08-09T08:08:32Z (UTC)
    出版者: TAIWAN ASSOC AEROSOL RES-TAAR
    ISSN: 1680-8584
    摘要: The use of electret N95 filtering facepiece respirators (N95FFRs) after prolonged storage or treatment can reduce the expense of buying non-expired N95 and thus enable developing and developed countries to optimize their use of limited resources to against airborne particles and diseases, such as coronavirus disease 2019 (COVID-19). The filtration performance of five N95FFR models following long-term storage, removal of charge using isopropanol alcohol (IPA), autoclaving, or treatment with gamma-radiation was assessed using a TSI 8130 automated filter tester. Statistically significant differences were found in the penetration (P), pressure drop (Delta p) and quality factor (q(f)) between non-expired and expired N95 models 3M-8210 and 3M-8511. A statistically significant linear correlation was also obtained between the N95 penetration ratio (PR) and the difference between year of manufacture and time of test (DYM). The PR of N95 was more strongly influenced by eliminating the charge (for extremely out-of-date respirators) on the electret filter than by the DYM. Sterilization by gamma irradiation increased the P into non-expired and expired N95FFR models (p < 0.05), reducing their q(f). The q(f) of all N95FFR models, except UVEX-3200, was strongly affected by gamma irradiation, the removal of charge using IPA, autoclaving, and storage in that order. All expired models maintained acceptable filtration performance and still could be used to collect aerosol effectively, even though models 3M-8511 and 3M-1860 had been manufactured up to 13 years previously. As the COVID-19 outbreaks in 2019 and is getting worse in 2020, these data are useful in developing a global stockpiling strategy to maximize the longevity of N95FFRs for public health and healthcare workers. However, the aging of the straps and seal materials (rubbers, plastics) of the N95FFRs may affect their fit factor and effectiveness.
    URI: http://dx.doi.org/10.4209/aaqr.2019.12.0620
    https://www.webofscience.com/wos/woscc/full-record/WOS:000522731600015
    https://ir.csmu.edu.tw:8080/handle/310902500/24821
    關聯: AEROSOL AND AIR QUALITY RESEARCH ,2020 ,v20 ,issue 4 ,p833-843
    显示于类别:[中山醫學大學研究成果] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML191检视/开启


    SFX Query

    在CSMUIR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈