English  |  正體中文  |  简体中文  |  Items with full text/Total items : 17933/22952 (78%)
Visitors : 7346981      Online Users : 222
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.csmu.edu.tw:8080/ir/handle/310902500/24460


    Title: A novel computed tomography image synthesis method for correcting the spectrum dependence of CT numbers
    Authors: Chen, YW;Fang, HY;Wang, YC;Peng, SL;Shih, CT
    Keywords: computed tomography;spectrum dependence;image synthesis
    Date: 2020
    Issue Date: 2022-08-09T08:02:42Z (UTC)
    Publisher: IOP PUBLISHING LTD
    ISSN: 0031-9155
    Abstract: The quantitative evaluation of computed tomography (CT) images is widely investigated and applied in clinical diagnosis. However, the CT number of tissue can vary with scanners or applied tube voltages because of the x-ray spectrum dependence of measured linear attenuation coefficients that degrades evaluation accuracy and limits multicenter or multimodality research. This study proposed a novel CT image synthesis method to correct the spectrum dependence of CT numbers by normalizing them to the same spectrum condition. Stoichiometric calibration was performed to derive the spectrum characteristic parameters (SCPs) of six spectra from two CT scanners with different applied tube voltages. Subsequently, conversion relationships between CT numbers and tissue parameters (TPs) were determined using the SCPs and standard tissue data. The CT number of a tissue measured from a spectrum condition was converted to TPs using these relationships, and the results were used to estimate the CT number of the tissue in another spectrum condition using the corresponding SCPs. Phantom, cadaver, and patient studies were performed to evaluate the proposed method. In the phantom study, image synthesis reduced the mean difference between the CT numbers of tissue-equivalent phantoms measured using different spectra from 57.96 to 33.94 HU. In the cadaveric study, the mean difference between the CT numbers of a temporal bone flap measured using different spectra was lowered by over 57%. In the patient image study, a significant difference of 81.5 HU was observed between the mean CT numbers of femoral shafts obtained from the two scanners; this difference was reduced to less than 17 HU, which was nonsignificant, when the proposed method was used. The proposed image synthesis method could reduce the spectrum dependence of CT numbers measured with different spectra and could be applied clinically to improve the accuracy of multicenter and multimodality evaluation and research.
    URI: http://dx.doi.org/10.1088/1361-6560/ab5fff
    https://www.webofscience.com/wos/woscc/full-record/WOS:000520112800001
    https://ir.csmu.edu.tw:8080/handle/310902500/24460
    Relation: PHYSICS IN MEDICINE AND BIOLOGY ,2020 ,v65 ,issue 2
    Appears in Collections:[中山醫學大學研究成果] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML159View/Open


    SFX Query

    All items in CSMUIR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback