English  |  正體中文  |  简体中文  |  Items with full text/Total items : 17933/22952 (78%)
Visitors : 7338767      Online Users : 521
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: https://ir.csmu.edu.tw:8080/ir/handle/310902500/24398


    Title: TLD environmental monitoring of new scanner facilities at the Nuclear Medicine Department of the Taiwan Medical University Hospital
    Authors: Le, YY;Weng, JH;Lee, TM;Lee, YC;Kao, PF;Pan, LK;Chen, CY
    Keywords: Environmental radiation rates;thermoluminescence dosimeter;SPECT;DXA;Nuclear Medicine Department;minimum detectable dose
    Date: 2020
    Issue Date: 2022-08-09T08:01:39Z (UTC)
    Publisher: IOS PRESS
    ISSN: 0928-7329
    Abstract: OBJECTIVE: Single-photon emission computed tomography (SPECT) as well as dual energy X-ray absorptiometry (DXA) scanners were designed in July 2018 at the Nuclear Medicine Department (NM), of the Taiwan Medical University Hospital. These scanners emit substantial X-rays from the target, which are tungsten, iron. Therefore, patients undergoing SPECT and DXA diagnosis, in addition to medical personnel, are exposed to undesirable photon leakage. METHODS: Following administration of radiopharmaceuticals, patients become radioactive sources; thus, it is necessary to evaluate a possible increase in the environmental gamma exposure rates in the NM as a result of the operation of the new scanners. A three month evaluation of environmental radiation in the NM was performed using the accurate and sensitive TLD-100H approach, which gives an error rate less than 10%. RESULTS: Detected exposure radiation rates in the NM ranged from 0.12 +/- 0.02 to 1.00 +/- 0.15 mSv per month, indicating that the imaging room had significantly different radiation rates. The results were compared with previous results, and no significant contribution to the enhancement of environmental gamma radiation was detected, which remained far below the occupational dose recommended by ICRP 60. The minimum detectable dose (MDD) for environmental radiation is also discussed herein to demonstrate the reliability of TLD-100H. CONCLUSION: Recommendations were sent to the authorities of AEC-ROC to implement actions that could reduce doses at these high-dose locations to meet the ALARA principle.
    URI: http://dx.doi.org/10.3233/THC-209015
    https://www.webofscience.com/wos/woscc/full-record/WOS:000541700200015
    https://ir.csmu.edu.tw:8080/handle/310902500/24398
    Relation: TECHNOLOGY AND HEALTH CARE ,2020 ,v28 S151-S160
    Appears in Collections:[中山醫學大學研究成果] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML245View/Open


    SFX Query

    All items in CSMUIR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback