English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 17918/22933 (78%)
造访人次 : 7430053      在线人数 : 46
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.csmu.edu.tw:8080/ir/handle/310902500/24275


    题名: Development of wearable posture monitoring system for dynamic assessment of sitting posture
    作者: Wu, CC;Chiu, CC;Yeh, CY
    关键词: Wearable;Dynamic measured unit;Feedback system
    日期: 2020
    上传时间: 2022-08-09T07:59:37Z (UTC)
    出版者: SPRINGER
    ISSN: 2662-4729
    摘要: There have been increasing cases of people seeking treatment for neck and back pain. The most common cause of neck and back pain is due to long-term poor sitting posture. The most common poor sitting posture cases are humpback, and head and neck being too far forward. It is easy to cause neck and back pain and other symptoms. Therefore, the development of wearable posture monitoring system for dynamic assessment of sitting posture becomes both helpful and necessary. In addition to recording the wearer's posture when sitting with quantitative assessment, it is needed to execute real-time action feedback for correctness of posture, in order to reduce neck and back pain due to long-term poor sitting posture. This study completed an instant recording and dynamic assessment of position measurement and feedback system. The system consists of a number of dynamic measurement units that can describe the posture trajectory, which integrates three-axis gyro meter, three-axis accelerometer, and magnetometer in order to measure the dynamic tracking. In the reliability analysis experiment, angle measurement error is less than 2%. The correlation coefficient between correlation analysis and Motion Analysis (MA) is 0.97. It is shown that the motion trajectory of this system is highly correlated with MA. In the feasibility test of sitting position detection, it is possible to detect the sitting position from the basic action of the walking, standing, sitting and lying down, and the sensitivity reaches 95.84%. In the assessment of the sitting position, the information published by the Canadian Centre for Occupational Health and Safety was used, as well as the recommendations of professional physicians as a basis for evaluating the threshold of the sitting measurement parameters and immediately feedback to the subjects. The system developed in this study can be helpful to reduce neck and back pain due to long- term poor sitting posture.
    URI: http://dx.doi.org/10.1007/s13246-019-00836-4
    https://www.webofscience.com/wos/woscc/full-record/WOS:000525685600020
    https://ir.csmu.edu.tw:8080/handle/310902500/24275
    關聯: PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE ,2020 ,v43 ,issue 1 ,p187-203
    显示于类别:[中山醫學大學研究成果] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML195检视/开启


    SFX Query

    在CSMUIR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈