    题名: Changes in skin surface temperature at an acupuncture point with moxibustion
    作者: LM, Lin
    SF, Wang
    RP, Lee
    BG, Hsu
    NM, Tsai
    TC, Peng
    贡献者: 中山醫學大學
    关键词: Acupuncture
    日期: 2013
    上传时间: 2016-09-05T07:31:11Z (UTC)
    ISSN: 0964-5284
    摘要: OBJECTIVE:
    This study evaluates the thermographic changes associated with moxa burner moxibustion at the SP6 acupuncture point to establish an appropriate, safe distance of efficacy for moxibustion.
    METHODS:
    Baseline temperature changes using a moxa burner were obtained for a paper substrate at various distances and times, and the tested with volunteers in a pilot study. A single-group trial was then conducted with 36 healthy women to monitor temperature changes on the body surface at the acupuncture point (SP6).
    RESULTS:
    Based on the temperature changes seen for the paper substrate and in the pilot study, a distance of 3 cm was chosen as the intervention distance. Moxibustion significantly increased the SP6 point skin surface temperature, with a peak increase of 11°C at 4 min (p <0.001). This study also found that during moxibustion the temperature of the moxa burner's rubber layer and moxa cautery were 56.9±0.9°C and 65.8±1.2°C, as compared to baseline values of 35.1°C and 43.8°C (p<0.001).
    CONCLUSIONS:
    We determined 3 cm was a safe distance between the moxa burner and acupuncture point. Moxibustion can increase the skin surface temperature at the SP6 point. This data will aid traditional Chinese medicine (TCM) practitioners in gauging safer treatment distances when using moxibustion treatments.
    URI: http://dx.doi.org/10.1136/acupmed-2012-010268
    https://ir.csmu.edu.tw:8080/ir/handle/310902500/15899
    關聯: Acupunct Med. 2013 Jun;31(2):195-201
    显示于类别:[醫學檢驗暨生物技術學系暨碩士班] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML325检视/开启


    SFX Query

    在CSMUIR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈