中山醫學大學機構典藏 CSMUIR:Item 310902500/11930
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 17935/22950 (78%)
造访人次 : 7501616      在线人数 : 622
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.csmu.edu.tw:8080/ir/handle/310902500/11930


    题名: Repeated measurements of urinary methylated/oxidative DNA lesions, acute toxicity, and mutagenicity in coke oven workers.
    作者: Chao MR;Wang CJ;Wu MT;Pan CH;Kuo CY;Yang HJ;Chang LW;Hu CW
    贡献者: 中山醫學大學
    日期: 2008-12
    上传时间: 2015-08-05T03:45:58Z (UTC)
    摘要: We conducted a repeated-measures cohort study of coke oven workers to evaluate the relationships between the traditional exposure biomarker, urinary 1-hydroxypyrene (1-OHP), and a series of biomarkers, including urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG), N7-methylguanine (N7-MeG), acute toxicity, and mutagenicity. A total of eight spot urine samples were collected from each high-exposed (at topside oven area) and low-exposed workers (at side oven area) during the whole working cycle, which consisted of 6 consecutive days of working followed by 2 days off. Our results showed that the high-exposed workers had significantly higher urinary levels of 1-OHP, 8-oxodG, and N7-MeG compared with the low-exposed workers. Acute toxicity and mutagenicity of urine were also found to be markedly increased in the high-exposed workers, as determined by Microtox assay and Ames test, respectively. Multivariate regressions analysis revealed that the urinary 8-oxodG, N7-MeG, or acute toxicity was significantly correlated with 1-OHP concentrations. Overall, the present study showed that exposure to coke oven emissions increased oxidatively damaged DNA products and mutagenicity of urine, and for the very first time, such exposure was also found to increase DNA methylation and urinary acute toxicity. The potential source of methylating agents in coke oven emissions warrants further investigation. Additionally, with repeated measurements, the pattern of time course for urinary 1-OHP was found to be different from those of 8-oxodG and N7-MeG, as well as acute toxicity and mutagenicity. This finding implies that the single measurement that was often conducted in occupational healthy investigations should be used with certain precautions, because single measurement may fail to provide the proper information of interest.
    URI: https://ir.csmu.edu.tw:8080/ir/handle/310902500/11930
    關聯: Cancer Epidemiol Biomarkers Prev. 2008 Dec;17(12):3381-9
    显示于类别:[公共衛生學系暨碩士班] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML325检视/开启


    SFX Query

    在CSMUIR中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈